瀚慖f not the specified value, replace the relay.
4. Install a 30-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Test
for less than 2 ohms between terminals 30 and 87.
瀚慖f greater than the specified range, replace the relay.
Repair Instructions
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* Relay Replacement (Attached to Wire Harness) (See: Power and Ground Distribution/Power Distribution Relay/Service and Repair/Relay
Replacement (Attached to Wire Harness))Relay Replacement (Within an Electrical Center) (See: Power and Ground Distribution/Power
Distribution Relay/Service and Repair/Relay Replacement (Within an Electrical Center))
* Control Module References (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming
P0650
DTC P0650
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.
* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure
Instructions) provide an overview of each diagnostic category.
DTC Descriptor
DTC P0650
- Malfunction Indicator Lamp (MIL) Control Circuit
Diagnostic Fault Information
Circuit/System Description
The malfunction indicator lamp (MIL) is located on the instrument panel cluster (IPC).
The MIL informs the driver that an emission system fault has occurred and that the engine control system requires service. The control module
monitors the MIL control circuit for conditions that are incorrect for the commanded states of the MIL.
Conditions for Running the DTC
* The ignition is in the Run or Crank position.
* The remote vehicle start is not active.
* The ignition voltage is at least 11 V and no more than 32 V.
* DTC P0650 runs continuously when the ignition is ON.
Conditions for Setting the DTC
The control module detects that the commanded state of the MIL driver and the actual state of the control circuit do not match for greater than 5 s.
Action Taken When the DTC Sets
DTC P0650 is a Type B DTC.
Conditions for Clearing the MIL/DTC
DTC P0650 is a Type B DTC.
Mercedes Benz Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.Mercedes,Mercedes,Benz,Mercedes-Benz UK,A,Class,B,Class,C,Class,E,Class,CLA,CLS,G,Class,GLA,A