2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 273

2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 273

* Lower Auxiliary Air Temperature Sensor

* Auxiliary Inside Air Temperature Sensor

A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance

decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +101掳C

(-40 to +215掳F). The sensor signal varies between 0-5 volts. The HVAC control module converts the signal to a range between 0-255 counts. As

the air temperature increases the count value will decrease. If the HVAC control module or auxiliary HVAC control module detects a

malfunctioning sensor, then the control module software will use a defaulted air temperature value. The default value for the ambient and inside air

temperature sensors will be displayed on the scan tool. The default value for the duct air temperature sensors will not be displayed on the scan tool.

The scan tool parameter for the duct air temperature sensors are the actual state of the signal circuit. The default action ensures that the HVAC

system can adjust the inside air temperature near the desired temperature until the condition is corrected.

Diagnostic Aids

Conditions for Running the DTC

Ignition ON.

Conditions for Setting the DTC

The HVAC control module detects the temperature sensor signal circuit is less than -36掳C (-38掳F) or greater than 215掳C (419掳F) for greater than 15

seconds.

Action Taken When the DTC Sets

The system operates using a default value.

Conditions for Clearing the DTC

* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.

* The history DTC will clear after 100 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air

Temperature Description and Operation)

* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery

Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic