Sunday, November 24, 2019

2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 446

2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 446

* The current DTC will clear when the module request for the output is removed or the malfunction is no longer present.

* A history DTC clears when the module ignition cycle counter reaches the reset threshold of 50, without a repeat of the malfunction.

Diagnostic Aids

Short to voltage in the run/crank relay coil control circuit will cause the malfunction indicator lamp (MIL) to illuminate with the ignition key OFF,

and the engine will remain running if started and the ignition key is removed.

Reference Information

Schematic Reference

* Body Control System Schematics (See: Body and Frame/Body Control Systems/Diagrams/Electrical Diagrams)

* Power Distribution Schematics (See: Diagrams/Electrical Diagrams/Starting and Charging/Power and Ground Distribution/System

Diagram/Power Distribution Schematics)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Power Mode Description and Operation (See: Power and Ground Distribution/Description and Operation/Power Mode Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Testing

1. Ignition OFF, disconnect the Run/Crank relay.

2. Connect a test lamp between the relay coil control circuit terminal 86 and ground.

3. Cycle the ignition ON and OFF. The test lamp should turn ON and OFF when changing ignition switch positions.

瀚慖f the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.

瀚慖f the test lamp is always OFF, test the control circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the

BCM.

4. If all circuits test normal, test or replace the Run/Crank relay.

Component Testing

1. Ignition OFF, disconnect the Run/Crank relay.

2. Test for 70-150 ohms between terminals 85 and 86.

瀚慖f the resistance is not within the specified range, replace the relay.

3. Test for infinite resistance between the following terminals:

* 30 and 86

* 30 and 87

* 30 and 85

* 85 and 87

瀚慖f less than specified, replace the relay.

4. Install a 3-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground.

Measure for less than 5 ohms between terminals 30 and 87.

瀚慖f greater than specified, replace the relay.

No comments:

Post a Comment