Friday, November 8, 2019

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 1418

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 1418

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Special Tools

* EL-48571 High Voltage Battery Pin Out Box

* EL-48900 HEV Safety Kit

Circuit/System Verification

Ignition ON, observe the scan tool Hybrid Battery 1-20 parameters. Each reading should be between 10-19 V, and all readings should be within 1.5

V of each other.

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection.

Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures

must be followed.

Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:

* Safety glasses with appropriate side shields when within 50 feet of the vehicle, either indoors or outdoors.

* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.

- Visually and functionally inspect the gloves before use.

- Wear the Insulation gloves at all times when working with the high voltage battery assembly, whether the system is energized or

not.

Failure to follow the procedures exactly as written may result in serious injury or death.

1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling ().

2. Disconnect the X4 harness connector at the drive motor battery control module.

3. Connect to the EL-48571 high voltage battery pin out box.

4. Install the high voltage manual disconnect lever. Measure and record each of the 20 battery voltages.

5. Each battery voltage reading should be between 10-19 V.

瀚慖f not within the specified range, replace the drive motor battery assembly.

6. Each battery voltage reading should be within 1.5 V of each other.

瀚慖f not within the specified range, replace the drive motor battery assembly.

7. If all circuits test normal, replace the drive motor battery control module.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the repair.

* Drive Motor Generator Battery Replacement and Shipping Preparation ()

* Control Module References (See: Testing and Inspection/Programming and Relearning) for drive motor generator battery control module

replacement, setup and programming

P0B56

DTC P0B3D, P0B42, P0B47, P0B4C, P0B51, P0B56, P0B5B, P0B60, P0B65, P0B6A, P0B6F, P0B74, P0B79, P0B7E, P0B83, P0B88, P0B8D,

P0B92, P0B97, or P0B9C

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

No comments:

Post a Comment