- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test sequence
- Measure direct current with multimeter between sockets [F.4] 100 and [M.1] 1 of the 126-pole socket box tester.
- Switch on ignition.
Testing of maximum power consumption may be conducted for no longer than 5 s.Specified value
- Amperage[1.0...1.8] A
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f43 (Fuse 43)
- Line from component Y49/5 (Right camshaft intake solenoid) to component N3/10 (ME-SFI [ME] control unit)
- Y49/5 (Right camshaft intake solenoid)
End of test
0279
Component Y49/5 (Right camshaft intake solenoid) has an open circuit in the wiring. (P0010)
Possible cause:
- Y49/5 (Right camshaft intake solenoid)
- N10/1kI (Circuit 87 relay, engine)
- N10/1f43 (Fuse 43)
- Voltage supply via component Z7/38 (Circuit 87 M1i connector sleeve)