2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction
none
2A3F - P1056 (DME)
2A3F - P1056
Information saved in
DME
Fault code
2A3F - P1056
Fault text
Valvetronic, actuator motor: power supply
Fault description
VVT-Supply Voltage Control Motor Low Input (Bank 1)
Condition for fault identification
Test condition:
VVT servo motor power supply monitor Terminal condition: Terminal 15 ON Voltage condition:
Electrical system voltage terminal 87 >10.0 V
Condition for fault memory entry
Power supply voltage < 5.75V
Action in service
Check VVT power supply voltage with multimeter. Supply voltage must lie between 5.75V and 17V.
If result is outside specified range: Inspect the power- supply wire to the VVT pins and check the plug.
If contact is stretched or corroded: Replace plug 4. If wiring harness is defective: Replace wiring harness.
Fault effect and breakdown warning
Driver information Warning light: MIL ON
No comments: