2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction



none









2A3F - P1056 (DME)



2A3F - P1056







Information saved in



DME









Fault code



2A3F - P1056









Fault text



Valvetronic, actuator motor: power supply









Fault description



VVT-Supply Voltage Control Motor Low Input (Bank 1)









Condition for fault identification



Test condition:





VVT servo motor power supply monitor Terminal condition: Terminal 15 ON Voltage condition:





Electrical system voltage terminal 87 >10.0 V









Condition for fault memory entry



Power supply voltage < 5.75V









Action in service



Check VVT power supply voltage with multimeter. Supply voltage must lie between 5.75V and 17V.



If result is outside specified range: Inspect the power- supply wire to the VVT pins and check the plug.



If contact is stretched or corroded: Replace plug 4. If wiring harness is defective: Replace wiring harness.







Fault effect and breakdown warning







Driver information Warning light: MIL ON