Test prerequisite



- The actual value is not o.k.



Test sequence



- Switch off ignition.



- Detach coupling at component B2/5 (Hot film mass air flow sensor).



- Measure direct voltage with multimeter between sockets (B2/5) 2 and (B2/5) 1



- Switch on ignition.



Specified value



- Voltage[11.0...15.0] V



Question



- Is the measurement value OK?



YES



The actual value is okay.Further possible causes of fault



- Unmetered air



- Signal wire



- B2/5 (Hot film mass air flow sensor)



End of test



NO



The measurement value is not OK.Possible cause and remedy



- N10/1f43 (Fuse 43)



- Cable for voltage supply



End of test



2. Check self-adaptation of mixture formation.



Test sequence



- Check actual value Selfadaptation of mixture formation.



- Carry out the following tests.



Continue with button F2