2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction
none
2AD8 - P143E (DME)
2AD8 - P143E
Information saved in
DME
Fault code
2AD8 - P143E
Fault text
EAC sensor, monitoring
Fault description
Direct Ozone Reduction Catalyst Temperature Sensor Gradient Too Low
Condition for fault identification
Test condition:
Coolant temperature > 86 锟斤拷C, Coolant temperature at radiator discharge >40 锟斤拷C --> meaning thermostat is certainly open and the EAC sensor in valid temperature range
Terminal condition: none Voltage condition:
UBatt >10 V
Condition for fault memory entry
at least twice (more often as required) Drive at least 30 sec. as during acceleration from rest in urban traffic
Action in service
Check temperature gradient (Service Test); install new sensor as indicated
Fault effect and breakdown warning
Driver information Warning light: MIL in 2nd DC
No comments: