2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction



none









2AB6



2AB6 - P16A5







Information saved in



DME









Fault code



2AB6 - P16A5









Fault text



DME, internal fault: multiple output-stage module









Fault description



Timeout Control Module Multiple Output Stage SPI-Bus









Condition for fault identification



Test condition:





Driver circuit monitor





Terminal condition: Terminal 15 ON Voltage condition:





none









Condition for fault memory entry



Yes, by event counter. Fault must occur ten times before a fault memory entry is made.









Action in service



Determine whether fault is stored again after carrying out the following procedure. If yes: Replace DME.





Clear fault memory



Ignition off, allow vehicle to assume complete dormant status



Ignition on



Read out stored fault codes from fault memory







Fault effect and breakdown warning







Driver information



Warning light:





No warning message. No control activation possible from some DME output terminals.