- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test sequence
- Measure direct current with multimeter between sockets [F.4] 100 and [M.48] 48 of the 126-pole socket box tester.
- Switch on ignition.
Testing of maximum power consumption may be conducted for no longer than 5 s.Specified value
- Amperage[1.0...1.8] A
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f43 (Fuse 43)
- Line from component Y49/4 (Left camshaft intake solenoid) to component N3/10 (ME-SFI [ME] control unit)
- Y49/4 (Left camshaft intake solenoid)
End of test
0301
The injection valve output stage of cylinder 1 detects a short circuit to positive. (P0262)
Possible cause:
- Y62y1 (Fuel injector cylinder 1)
Affected functions:
- Engine diagnosis
- Engine running
-------------------------------------------------
No comments: