- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test sequence
- Measure direct current with multimeter between sockets [F.4] 100 and [M.24] 24 of the 126-pole socket box tester.
- Switch on ignition.
Testing of maximum power consumption may be conducted for no longer than 5 s.Specified value
- Amperage[1.0...1.8] A
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f43 (Fuse 43)
- Line from component Y49/7 (Right camshaft exhaust solenoid) to component N3/10 (ME-SFI [ME] control unit)
- Y49/7 (Right camshaft exhaust solenoid)
End of test
0069
Component Y49/6 (Left camshaft exhaust solenoid) has a short circuit to positive. (P2091)