Test 2.1.5.3: Perform mechanical inspection of component Y58/1 (Purge control valve).
2.1.5.1. Actuate component Y58/1 (Purge control valve).
Test sequence
- Switch on ignition.
- Actuate component Y58/1 (Purge control valve).(Operate pushbutton F2.)
Warning!Communication with ECU required.
2.1.5.2. Test current consumption of component Y58/1 (Purge control valve).
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test prerequisite
- The actual values are not okay.
Test sequence
- Measure direct current with multimeter between socket [F.4] 100 of the 126-pole socket box tester and socket [F.45] 15 of the 35-pole socket
box tester.
- Switch on ignition.
Specified value
- Amperage[0.4...0.9] A