Sunday, February 17, 2019

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 973


- Switch off ignition.



- Detach coupling at component B2/5 (Hot film mass air flow sensor).



- Measure direct voltage with multimeter between sockets (B2/5) 2 and (B2/5) 1



- Switch on ignition.



Specified value



- Voltage[11.0...15.0] V



Question



- Is the measurement value OK?



YES



The actual value is okay.Further possible causes of fault



- Unmetered air



- Signal wire



- B2/5 (Hot film mass air flow sensor)



End of test



NO



The measurement value is not OK.Possible cause and remedy



- N10/1f43 (Fuse 43)



- Cable for voltage supply



End of test



2. Check component M16/6 (Throttle valve actuator).



Test 2.1: Check component M16/6 (Throttle valve actuator) using actual value.



Test 2.2: Check component M16/6m1 (Actuator motor) by means of actuation.



Test 2.3: Check internal resistance of component M16/6m1 (Actuator motor).



Test 2.4: Check internal resistance of component M16/6 (Throttle valve actuator).



Test 2.5: Test voltage supply of the potentiometers of component M16/6 (Throttle valve actuator).



2.1. Check component M16/6 (Throttle valve actuator) using actual value.



Warning!Communication with ECU required.