Mercedes Benz C 43 AMG Technical Service Bulletin # P-82_85-170 Date: 010913

Mercedes Benz C 43 AMG Technical Service Bulletin # P-82_85-170 Date: 010913



COMAND(R) System - Incorrect ETA Calculation Displayed



Date: September 13, 2001



Order No.: P-B-82.85/170



145



Supersedes:



Group: 82



SUBJECT:



All Models With COMAND



Estimated Time Of Arrival Calculation Is 12 hours Longer Than Actual ETA



It is possible that during Navigation route guidance COMAND might calculate the ETA 12 hours longer than actual ETA. This symptom if it arises



most likely would occur when the route guidance will pass through noon time. This symptom does not occur when the clock on COMAND is set to



the 24-hour time mode. If you encounter this condition, do not replace the COMAND unit. The condition can be addressed if the customer consents



to setting the COMAND unit to the 24-hour time mode. The supplier is currently working on a software update to address the symptom in the

No comments: