2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Technical Service Bulletin # 12-069 Date: 120820
A/C - Does Not Cool Enough/Poor Performance
Classification: HA12-009
Reference: NTB12-069
Date: August 20, 2012
2007 - 2012 ALTIMA AND 2009 - 2012 MAXIMA;
A/C IS NOT COOLING / POOR PERFORMANCE
APPLIED VEHICLES: 2007 - 2012 Altima Sedan and Coupe (L32 / CL32)
2009 - 2012 Maxima (A35)
IF YOU CONFIRM
The A/C system is not cooling the cabin to factory specification,
and
The A/C compressor clutch is engaged,
and
2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Page 85
The A/C system is fully charged,
and
The HVAC system doors and controls are working correctly.
ACTIONS
1. Check the A/C system pressures:
^ If the A/C system pressures are HIGH side low and LOW side low, go to step 2.
^ If the A/C pressures are any other then above, this bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic
information.
2. By feel, or with an infrared thermometer; check the temperature of the condenser / receiver dryer outlet tube.
^ Tube is Warm or Hot: This bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic information.
^ Tube is Cool or Cold: Replace the condenser and receiver dryer assembly.
PARTS INFORMATION
CLAIMS INFORMATION
SERVICE PROCEDURE:
1. Check the A/C system pressures:
^ Refer to the appropriate Service Manual for system pressure specifications.
^ If the A/C system pressures are: HIGH side = low and LOW side = low, go to step 2 below.
^ If the A/C pressures are any other then above, this bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic
information.
2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Page 86
2. By feel, or with an infrared thermometer; check the temperature of the receiver dryer outlet tube.
^ Tube is Warm or Hot: This bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic information.
^ Tube is Cool or Cold: Replace the condenser and receiver dryer assembly.
Refer to the appropriate Service Manual for replacement information. Follow all Service Manual warnings and cautions as applicable.
NOTE:
^ Cool or Cold receiver dryer outlet tube indicates a blockage in the receiver dryer or condenser.
^ If desired, the filter can be removed from the receiver dryer to confirm the root cause of the issue was blockage (debris) in the receiver
dryer.
^ Figure 2 shows an example of a receiver dryer filter that is bowed and plugged with debris.