2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Technical Service Bulletin # 12-069 Date: 120820



A/C - Does Not Cool Enough/Poor Performance



Classification: HA12-009



Reference: NTB12-069



Date: August 20, 2012



2007 - 2012 ALTIMA AND 2009 - 2012 MAXIMA;



A/C IS NOT COOLING / POOR PERFORMANCE



APPLIED VEHICLES: 2007 - 2012 Altima Sedan and Coupe (L32 / CL32)



2009 - 2012 Maxima (A35)



IF YOU CONFIRM



The A/C system is not cooling the cabin to factory specification,



and



The A/C compressor clutch is engaged,



and



2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Page 85



The A/C system is fully charged,



and



The HVAC system doors and controls are working correctly.



ACTIONS



1. Check the A/C system pressures:



^ If the A/C system pressures are HIGH side low and LOW side low, go to step 2.



^ If the A/C pressures are any other then above, this bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic



information.



2. By feel, or with an infrared thermometer; check the temperature of the condenser / receiver dryer outlet tube.



^ Tube is Warm or Hot: This bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic information.



^ Tube is Cool or Cold: Replace the condenser and receiver dryer assembly.



PARTS INFORMATION



CLAIMS INFORMATION



SERVICE PROCEDURE:



1. Check the A/C system pressures:



^ Refer to the appropriate Service Manual for system pressure specifications.



^ If the A/C system pressures are: HIGH side = low and LOW side = low, go to step 2 below.



^ If the A/C pressures are any other then above, this bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic



information.



2010 Nissan-Datsun Altima L4-2.5L (QR25DE) Page 86



2. By feel, or with an infrared thermometer; check the temperature of the receiver dryer outlet tube.



^ Tube is Warm or Hot: This bulletin does not apply. Refer to ASIST and the Service Manual for further diagnostic information.



^ Tube is Cool or Cold: Replace the condenser and receiver dryer assembly.



Refer to the appropriate Service Manual for replacement information. Follow all Service Manual warnings and cautions as applicable.



NOTE:



^ Cool or Cold receiver dryer outlet tube indicates a blockage in the receiver dryer or condenser.



^ If desired, the filter can be removed from the receiver dryer to confirm the root cause of the issue was blockage (debris) in the receiver



dryer.



^ Figure 2 shows an example of a receiver dryer filter that is bowed and plugged with debris.