- Switch on ignition.
Specified value
- Voltage[11.0...15.0] V
Question
- Are the measurement values OK?
YES
The measurement values are OK.Further possible causes of fault
- Test voltage supply of circuit 30.
NO
The measurement values are not OK.Possible cause and remedy
- N10/1f43 (Fuse 43)
- N10/1f44 (Fuse 44)
- N10/1kI (Circuit 87 relay, engine)
- Lines
- N10/1 (Driver-side SAM control unit with fuse and relay module)
End of test
3.4. Test current consumption of component N10/1kR (Circuit 87 relay, engine).
Connect socket box to component N3/10 (ME-SFI [ME] control unit).
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
-
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2