NO
The measurement value is not OK.Possible cause and remedy in the case of undervoltage
- Lines between N93 (Central gateway control unit) and
- Lines between N93 (Central gateway control unit) and
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Lines between and
- G1 (Battery)
- G2 (generator)
End of test
1.3.2.1.10. Check power supply at control unit Y3/8n4 (Fully integrated transmission control (VGS) control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641Test sequence
- Switch off ignition.
- Separate plug connection at transmission.
- Measure voltage in transmission wiring harness using a multimeter.
- Switch on ignition.
Measure direct voltage with multimeter between 5 and 4Specified value:
- Voltage[8,5...16,4] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause of fault
- The conductors in the electrohydraulic control unit are interrupted.
- Component Y3/8n4 (Fully integrated transmission control (VGS) control unit) is defective.
Possible remedy
- Replace component Y3/8 (Electric control unit (VGS)).
Following the repair measures, the following checks MUST be carried out using the Diagnosis Assistance System, menu 'Initial startup'
- Initial startup with manual settings input for new control unit
No comments:
Post a Comment